Hydrogen Mass Flow Meter Micro Gas Mass Flow Controller Silane Flow Meter
Description:
We can supply Hydrogen Mass Flow Meter Micro Gas Mass Flow Controller Silane Flow Meter
Technical Parameter
FLOWMETER
Medium:Suitable for gases, weakly corrosive gases such as: nitrogen, air, not suitable for ammonia
Accuracy :+/-1.0%
linearity:+/-0.5%F.S
Repeatability:+/-0.2%F.S
Response time:<1.5s
Communication:RS232/485,MODBUS(Digital)
Output:0~5V,1~5V,4-20mA
Power supply:+/-15VDC,24VDC
Temperature:0~50°C
Work pressure:<0.01Mpa
Maximum withstand pressure:3Mpa/10Mpa
Electrical interfaces:DB15hole
Leakage rate:1×10-9SCCSHe
Temperature coefficient:+/-0.025%F.S/°C
Base Material:SS316L
Sealing material:Viton, neoprene, nitrile
Joint:∅03,∅06,1/8”,1/4′
CONTROLLER
Medium:Suitable for gases, weakly corrosive gases such as: nitrogen, air, not suitable for ammonia
Accuracy :+/-1.5%F.S
linearity:+/-0.5%F.S
Repeatability:+/-0.2%F.S
Response time:<2.0s
Communication:RS232/485,MODBUS
Output:0~5V,1~5V,4-20mA
Power supply:+/-15VDC,24VDC
Temperature:0~50°C
Work pressure:Differential Pressure:0.1~0.5Mpa
Maximum withstand pressure:3Mpa/10Mpa
Electrical interfaces:DB15hole
Leakage rate:1×10-9SCCSHe
Temperature coefficient:+/-0.025%F.S/°C
Base Material:SS316L
Sealing material:Viton, neoprene, nitrile
Joint:∅8,∅10,∅12
CX-GMFM flow range
NOTE: THE CONTROLLER IS THE SAME AS THE FLOW METER
| Model | Flow range | Connection size |
| CX-F1 | 0~10sccm | 6mmCompression fittings |
| CX-F2 | 0.3~30slm | 6mmCompression fittings |
| CX-F3 | 1.5~150slm | 6mmCompression fittings |
| CX-F4 | 2.5~250slm | 10mmCompression fittings |
| CX-F5 | 10~1000slm(Digital) | 12mmCompression fittings |
| CX-F6 | 20~2000slm(Digital) | 12mmCompression fittings |
| CX-F7 | 30~3000slm(Digital) | 12mmCompression fittings |