Description:
Three-phase transformer generally refers to the transformer’s primary and secondary windings are electrically completely isolated, which can effectively remove the third harmonic and suppress various interferences;
Due to the discord connection of the secondary to the ground, there is no potential difference between any line of the secondary and the ground, which reduces all kinds of clutter and interference. For AC 50/60Hz,
Various three-phase power supply occasions with input and output voltages not exceeding AC1000V. It has the characteristics of wide range of applicable loads, can withstand instantaneous overload, can work continuously for a long time, is safe and reliable, saves energy and is convenient for maintenance. The input and output voltage of the product (three-phase or multi-channel input and output, etc.), the connection method,
Adjust the tap position, winding capacity distribution, secondary winding equipment, can be designed and manufactured according to the user’s requirements.
Different models could be supplied:
JBK-5KVA
JBK-10KVA
JBK-15KVA
Technical Parameter
| Type | Â Three-Phase Dry-Type Isolation Transformer, Class i Transformer |
| Rated Power | Â 50kva |
| Overload | Â 100% Continuous Work / 120% For 60 Minutes |
| Rated Input Voltage |  3ø Ac480v |
| Rated Input Current | Â 60a |
| Frequency | Â 50/60hz |
| Rated Output Voltage |  3ø Ac380v |
| Rated Output Current | Â 76a |
| Input Short-Circuit Protection Current | Â 72a |
| Output Short-Circuit Protection Current | Â 84a |
| Voltage Fluctuation |  ≤5% |
| Insulation Rating | Â Class f |
| Degree Of Protection | Â Ip20 |
| Dielectric Strength |  ≥100mω, Dc 500v |
| Dielectric Strength | Â Ac 5000v For 1 Minute |
| Efficiency |  ≥98% |
| Noise |  ≤60db |
| Coil Conductor | Â Copper Wire |
| Isolation | Â The Primary And Secondary Sides Need To Be Isolated With Copper Foil, Which Should Cover The Entire Coil Height |
| Interlayer Insulation | Â At Least One Layer Between Layers |
| Terminals | Â Ul Listed Terminals Or Copper Bars |
| Maximum Allowable Size (w×h×d) Mm |  900×550×850 |
| Connection | Â y/y |
| Temperature Rise |  100k Under Normal Working Conditions≤ |
| Cooling Method | Â Air Cooling |
Features
1. Made of high-quality high flux silicon steel sheet to ensure stable product performance and low loss;
2. The primary winding and the secondary winding are electrically completely isolated, which can effectively remove the third harmonic and suppress all kinds of interference;
3. The coil of the product is impregnated with vacuum pressure, cured and dried at high temperature, and the paint film is bright and uniform without cracking;
4. The product is safe, environmentally friendly, energy-saving, and has the characteristics of flame retardant, flame retardant, non-toxic, self-extinguishing, and fireproof;
5. It is suitable for a wide range of loads, can withstand instantaneous overload, and can work continuously for a long time.
Application
This transformer is suitable for different environments, including but not limited to workshops with metal dust, paint shops, humid environments by the sea, etc. If there is an environment that is not applicable, it needs to be raised in advance and the applicable data must be given. Altitude: Suitable for elevations below 1000 meters. Operating temperature: suitable for the ambient temperature range of -15°C~55°C, in the case of extreme temperature, it is necessary to put forward the possible consequences of operation. Storage temperature: suitable for the ambient temperature range of -25°C~70°C, in the case of extreme temperature, the possible consequences need to be proposed. Humidity: Suitable for relative humidity below 95% without condensation. Contamination: Suitable for applications with pollution level 3. Installation: Indoor use It is suitable for vibration applications within 5m/s2 (0.5G).